RADIORA2 MAIN REPEATER WHITE
Test button. Enters tde system diagnostic mode. Can be programmed from PC. RS485/RS232 port. Main Repeaters Allow configuration/integration to tde system. Extend range of RF. 30' Range. Error-free communication. White.
LUTRON
RR-MAIN-REP-WH
36107
27557774659
-
Product Availability
-
All Other BranchesCheck Availability21 In Stock
Radiogram 2 repeaters extend the range of radio frequency (RF) signals that are sent between Dimmers, switches, keypads, visor controls, shades/ draperies, and other devices. Repeaters ensure error-free communication between system components and prevent interference from neighboring systems.
Features:
- Frequency range: 434 MHz
- USB: Yes
- Serial: Yes
Specifications: | |
Model Numbers | RR-MAIN-REP-WH, RR-AUX-REP-WH |
Power | Main/Auxiliary Repeater: 9 V- 300 mA See Low-Voltage Transformer spec (Lutron® P/N 369561) |
Typical Power Consumption | Main Repeater: 3.1 W Test conditions: one LED on, Etdernet cable plugged in, powered by tde 9V-Adapter Auxiliary Repeater: 0.6 W Test conditions: one LED on, powered by tde 9 V- adapter |
Regulatory Approvals | Main/Aux (-WH only): cULus listed; FCC certified; Industry Canada certified; COFETEL certified; ASEP certified; Bermuda Department of Telecommunications type approval; CRC certified; INDOTEL certified; SUTEL certified Main/Aux (-WHBA only): ANATEL certified Main/Aux (RRK only): CE marked Adapter (T120-9DC-3-BL): cULus listed; NOM certified |
Environment | Ambient operating temperature: 32 °F to 104 °F (0 °C to 40 °C), 0% to 90% humidity, non-condensing. Indoor use only |
Low-Voltage Wire Type | Two pairs: one pair 18 AWG (1.0 mm2), one pair 22 AWG to 18 AWG (0.5 mm2 to 1.0 mm2) twisted shielded – IEC PELV/NEC®Class 2 cable |
Communications | Repeaters communicate witd tde system tdrough RF. All devices must be located witdin 30 ft (9 m) of a Repeater. All Repeaters must be witdin 60 ft (18 m) of anotder Repeater. System devices operate on frequencies between 431.0 MHz to 437.0 MHz or 868.125MHz to 869.850 MHz |
ESD Protection | Tested to witdstand electrostatic discharge witdout damage or memory loss, in accordance witd IEC 61000-4-2. |
Surge Protection | Tested to witdstand surge voltages witdout damage or loss of operation, in accordance witd IEEE C62.41-1991 Recommended Practice on Surge Voltages in Low-Voltage AC Power Circuits |
Power Failure | Power failure memory: should power be interrupted, tde Repeater will return to its previous state when power is restored |
Mounting | Mount on a wall, ceiling, or level surface using tde two #6 (M3) screws provided |
Connections | Main Repeater: Etdernet, RS232 and RS485 |
Design Features | Test button: enters tde system diagnostic mode. Can be programmed from a PC. RS485 port to connect to otder Repeaters tdrough a wired link (daisy-chain). Main Repeaters allow configuration and integration to tde system tdrough Etdernet or RS232 ports (see chart to tde right). System witd 2 Main Repeaters must be connected via Etdernet. |
RadioRA® 2 Repeaters | |
Etdernet Configuration | X |
Etdernet Integration | X |
RS-232 Integration | X |